DrugHub

Rubidium (Cardiogen-82)

Active ingredient · RxNorm 1311489 · Data updated Nov 29, 2026

About rubidium

Rubidium Chloride Rb 82 Injection, produced by generators such as CardioGen-82 and Ruby-Fill, is a radioactive diagnostic agent first approved by the FDA in 1989 [1][2]. It is used in positron emission tomography (PET) scans to evaluate blood flow in the heart muscle of adults with suspected or existing coronary artery disease [1]. Biologically, rubidium acts similarly to potassium, entering heart cells through ion exchange pumps [1]. It accumulates in healthy, viable heart tissue but is cleared from damaged or dead tissue [1]. The use of these generators carries a boxed warning regarding the risk of high radiation exposure if the incorrect solution is used for elution, which can lead to strontium breakthrough [1]. Currently, there are no marketed generic or biosimilar versions of these products [2]. Research on rubidium is extensive, with over 8,000 indexed articles and 23 clinical studies listed [3][4]. FDA records indicate two product recalls, neither of which were classified as Class I [5].

  1. [1] FDA drug label (DailyMed)
  2. [2] FDA Drugs@FDA / Orange Book
  3. [3] ClinicalTrials.gov
  4. [4] PubMed
  5. [5] FDA enforcement reports (openFDA)

Summary written by an AI model (google/gemini-2.5-flash-lite) from the cited public records, 11/29/2026. Check the sources before relying on it.

Key facts

First FDA approval
Dec 29, 1989

36 years on market

Brand applications
2
Generic applications
0

Competition: none (0 marketed)

Application holders
2
Clinical trials
23

0 recruiting now

PubMed articles
8,092
Medicare spend
Not reported
Recalls
2

0 Class I

Counts are calculated from FDA, ClinicalTrials.gov, PubMed and CMS records.

Boxed warning

WARNING: HIGH LEVEL RADIATION EXPOSURE WITH USE OF INCORRECT ELUENT and FAILURE TO FOLLOW THE ELUATE TESTING PROTOCOL High Level Radiation Exposure with Use of Incorrect Eluent Patients are exposed to high radiation levels when the CardioGen-82 generator is eluted with the incorrect eluent due to high strontium (Sr) 82 and Sr 85 breakthrough levels. Use only additive-free 0.9% Sodium Chloride Injection to elute the generator. If an incorrect solution is used to elute the CardioGen-82 generator: Immediately stop the patient infusion; Evaluate the patient’s radiation absorbed dose, and monitor f...

Show full text

or the effects of radiation to critical organs such as bone marrow; Permanently discontinue the use of the affected generator [see Dosage and Administration (2.5) and Warnings and Precautions (5.1) ]. Excess Radiation Exposure with Failure to Follow the Eluate Testing Protocol Excess radiation exposure occurs when the levels of Sr 82 or Sr 85 in the Rubidium Chloride Rb 82 Injection exceed specified limits. Strictly adhere to the generator eluate testing protocol, to minimize the risk of excess radiation exposure, including daily testing and additional testing at Alert Limits. Stop using the generator if it reaches any of its Expiration Limits: 17 L for the generator’s cumulative eluate volume 60 days post generator calibration date An eluate Sr 82 level of 0.01 microCi /mCi Rb 82 An eluate Sr 85 level of 0.1 microCi /mCi Rb 82 [see Dosage and Administration ( 2.5 , 2.6 , 2.7 , 2.8 ) and Warnings and Precautions ( 5.2 )] WARNING: HIGH LEVEL RADIATION EXPOSURE WITH USE OF INCORRECT ELUENT and FAILURE TO FOLLOW THE ELUATE TESTING PROTOCOL See full prescribing information for complete boxed warning. High Level Radiation Exposure with Use of Incorrect Eluent Using the incorrect eluent can cause high Strontium (Sr) 82 and Sr 85 breakthrough levels. Use only additive-free 0.9% Sodium Chloride Injection to elute CardioGen-82. If an incorrect solution is used to elute CardioGen-82: Immediately stop the patient infusion; Evaluate the patient’s radiation absorbed dose and monitor for the effects of radiation to critical organs such as bone marrow; Permanently discontinue use of the affected generator. ( 2.5 , 2.9 , 5.1 ) Excess Radiation Exposure with Failure to Follow the Eluate Testing Protocol Excess radiation exposure occurs when the levels of Sr 82 or Sr 85 in the Rubidium Chloride Rb 82 Injection exceed limits. Strictly adhere to the generator eluate testing protocol. Stop using the generator if it reaches any of its Expiration Limits. ( 2.5 , 2.6 , 2.7 , 5.2 )

What it is approved for

CardioGen-82, used to produce Rubidium Chloride Rb 82 Injection, is indicated for positron emission tomography (PET) of the myocardium under rest or pharmacologic stress conditions to evaluate regional myocardial perfusion in adult patients with suspected or existing coronary artery disease. CardioGen-82, used to produce Rubidium Chloride Rb 82 Injection, is a radioactive diagnostic agent indicated for positron emission tomography (PET) of the myocardium under rest or pharmacologic stress conditions to evaluate regional myocardial perfusion in adult patients with suspected or existing coronary artery disease. ( 1 )

Source: FDA label on DailyMed, revised May 14, 2026

How it works

12.1 Mechanism of Action Rb 82 is analogous to potassium ion (K + ) in its biochemical behavior and is extracted by the myocardium in proportion to the blood flow. Rb + participates in the sodium-potassium (Na + /K + ) ion exchange pumps that are present in cell membranes. The intracellular uptake of Rb 82 requires maintenance of ionic gradient across cell membranes. Rb 82 radioactivity is increased in viable myocardium reflecting intracellular retention, while the tracer is cleared from necrotic or infarcted tissue.

Source: FDA label on DailyMed, revised May 14, 2026

FDA approvals, generics and biosimilars

ApplicationTypeHolderApprovedProductsStatus
NDA019414Brand (NDA)BraccoDec 29, 1989CARDIOGEN-82 (1)Marketed
NDA202153Brand (NDA)JubilantSep 30, 2016RUBY-FILL (1)Marketed

Source: FDA Drugs@FDA / Orange Book, Purple Book

Clinical trials

See all: Clinical trials →

Source: ClinicalTrials.gov

Recent research

See all: Research →

Source: PubMed

Medicare Part D spending

No Medicare Part D spending reported.

Source: CMS Medicare Part D Spending by Drug

Recalls

  • Class II · Oct 3, 2012 · Bracco Diagnostics Inc

    GMP deviation; Sr-82 levels exceeded alert limit specification

    CARDIOGEN-82 (Rubidium Rb 82 Generator), 140 millicurie, Rx Only, For Elution of sterile nonpyrogenic Rubidium Chloride Rb 82, Manufactured for: Bracco Diagnostics Inc. Princeton, NJ 08543 by Medi-Physics, Inc. South Plainfield, NJ 07080, NDC 0270-0091-01

  • Class II · Aug 22, 2012 · Franck's Lab Inc., d.b.a. Franck's Compounding Lab

    Lack of Assurance of Sterility: Franck's Lab Inc. initiated a recall of all Sterile Human Drugs distributed between 11/21/2011 and 05/21/2012. FDA environmental sampling revealed the presence of microorganisms and fungal growth in the clean room where sterile products were prepared.

    RUBIDIUM 200MCG/ML INJECTABLE 30 ML (1 PRODUCT)

See all: Recalls →

Source: FDA enforcement reports via openFDA