Rubidium (Cardiogen-82)
Active ingredient · RxNorm 1311489 · Data updated Nov 29, 2026
Brand names
About rubidium
Rubidium Chloride Rb 82 Injection, produced by generators such as CardioGen-82 and Ruby-Fill, is a radioactive diagnostic agent first approved by the FDA in 1989 [1][2]. It is used in positron emission tomography (PET) scans to evaluate blood flow in the heart muscle of adults with suspected or existing coronary artery disease [1]. Biologically, rubidium acts similarly to potassium, entering heart cells through ion exchange pumps [1]. It accumulates in healthy, viable heart tissue but is cleared from damaged or dead tissue [1]. The use of these generators carries a boxed warning regarding the risk of high radiation exposure if the incorrect solution is used for elution, which can lead to strontium breakthrough [1]. Currently, there are no marketed generic or biosimilar versions of these products [2]. Research on rubidium is extensive, with over 8,000 indexed articles and 23 clinical studies listed [3][4]. FDA records indicate two product recalls, neither of which were classified as Class I [5].
- [1] FDA drug label (DailyMed)
- [2] FDA Drugs@FDA / Orange Book
- [3] ClinicalTrials.gov
- [4] PubMed
- [5] FDA enforcement reports (openFDA)
Summary written by an AI model (google/gemini-2.5-flash-lite) from the cited public records, 11/29/2026. Check the sources before relying on it.
Key facts
- First FDA approval
- Dec 29, 1989
- Brand applications
- 2
- Generic applications
- 0
- Application holders
- 2
- Clinical trials
- 23
- PubMed articles
- 8,092
- Medicare spend
- Not reported
- Recalls
- 2
36 years on market
Competition: none (0 marketed)
0 recruiting now
0 Class I
Counts are calculated from FDA, ClinicalTrials.gov, PubMed and CMS records.
Boxed warning
WARNING: HIGH LEVEL RADIATION EXPOSURE WITH USE OF INCORRECT ELUENT and FAILURE TO FOLLOW THE ELUATE TESTING PROTOCOL High Level Radiation Exposure with Use of Incorrect Eluent Patients are exposed to high radiation levels when the CardioGen-82 generator is eluted with the incorrect eluent due to high strontium (Sr) 82 and Sr 85 breakthrough levels. Use only additive-free 0.9% Sodium Chloride Injection to elute the generator. If an incorrect solution is used to elute the CardioGen-82 generator: Immediately stop the patient infusion; Evaluate the patient’s radiation absorbed dose, and monitor f...
Show full text
or the effects of radiation to critical organs such as bone marrow; Permanently discontinue the use of the affected generator [see Dosage and Administration (2.5) and Warnings and Precautions (5.1) ]. Excess Radiation Exposure with Failure to Follow the Eluate Testing Protocol Excess radiation exposure occurs when the levels of Sr 82 or Sr 85 in the Rubidium Chloride Rb 82 Injection exceed specified limits. Strictly adhere to the generator eluate testing protocol, to minimize the risk of excess radiation exposure, including daily testing and additional testing at Alert Limits. Stop using the generator if it reaches any of its Expiration Limits: 17 L for the generator’s cumulative eluate volume 60 days post generator calibration date An eluate Sr 82 level of 0.01 microCi /mCi Rb 82 An eluate Sr 85 level of 0.1 microCi /mCi Rb 82 [see Dosage and Administration ( 2.5 , 2.6 , 2.7 , 2.8 ) and Warnings and Precautions ( 5.2 )] WARNING: HIGH LEVEL RADIATION EXPOSURE WITH USE OF INCORRECT ELUENT and FAILURE TO FOLLOW THE ELUATE TESTING PROTOCOL See full prescribing information for complete boxed warning. High Level Radiation Exposure with Use of Incorrect Eluent Using the incorrect eluent can cause high Strontium (Sr) 82 and Sr 85 breakthrough levels. Use only additive-free 0.9% Sodium Chloride Injection to elute CardioGen-82. If an incorrect solution is used to elute CardioGen-82: Immediately stop the patient infusion; Evaluate the patient’s radiation absorbed dose and monitor for the effects of radiation to critical organs such as bone marrow; Permanently discontinue use of the affected generator. ( 2.5 , 2.9 , 5.1 ) Excess Radiation Exposure with Failure to Follow the Eluate Testing Protocol Excess radiation exposure occurs when the levels of Sr 82 or Sr 85 in the Rubidium Chloride Rb 82 Injection exceed limits. Strictly adhere to the generator eluate testing protocol. Stop using the generator if it reaches any of its Expiration Limits. ( 2.5 , 2.6 , 2.7 , 5.2 )
What it is approved for
CardioGen-82, used to produce Rubidium Chloride Rb 82 Injection, is indicated for positron emission tomography (PET) of the myocardium under rest or pharmacologic stress conditions to evaluate regional myocardial perfusion in adult patients with suspected or existing coronary artery disease. CardioGen-82, used to produce Rubidium Chloride Rb 82 Injection, is a radioactive diagnostic agent indicated for positron emission tomography (PET) of the myocardium under rest or pharmacologic stress conditions to evaluate regional myocardial perfusion in adult patients with suspected or existing coronary artery disease. ( 1 )
Source: FDA label on DailyMed, revised May 14, 2026
How it works
12.1 Mechanism of Action Rb 82 is analogous to potassium ion (K + ) in its biochemical behavior and is extracted by the myocardium in proportion to the blood flow. Rb + participates in the sodium-potassium (Na + /K + ) ion exchange pumps that are present in cell membranes. The intracellular uptake of Rb 82 requires maintenance of ionic gradient across cell membranes. Rb 82 radioactivity is increased in viable myocardium reflecting intracellular retention, while the tracer is cleared from necrotic or infarcted tissue.
Source: FDA label on DailyMed, revised May 14, 2026
FDA approvals, generics and biosimilars
| Application | Type | Holder | Approved | Products | Status |
|---|---|---|---|---|---|
| NDA019414 | Brand (NDA) | Bracco | Dec 29, 1989 | CARDIOGEN-82 (1) | Marketed |
| NDA202153 | Brand (NDA) | Jubilant | Sep 30, 2016 | RUBY-FILL (1) | Marketed |
Source: FDA Drugs@FDA / Orange Book, Purple Book
Clinical trials
- Parathyroid Adenoma Detection With Rubidium-82 Imaging
NCT07099404 · Phase not listed · enrolling by invitation · Matthieu Pelletier-Galarneau, MD MSc · started 2026-11 · 20 participants
- Dynamic 82-Rb Positron Emission Tomography (PET) for the Grading of KIDney Carcinoma
NCT07346404 · Phase 2 · not yet recruiting · Assistance Publique - Hôpitaux de Paris · started 2026-01-01 · 50 participants
- The FLARE (Flurpiridaz vs. Rubidium Evaluation) Trial
NCT07761728 · Phase not listed · enrolling by invitation · University of California, Los Angeles · started 2025-08-13 · 60 participants
- A Pilot Study Evaluating the Potential of 18F Fluorodeoxyglucose PET-CT Imaging in Diagnosing Cardiac Rejection.
NCT06519240 · Not applicable · unknown · Royal Brompton & Harefield NHS Foundation Trust · started 2024-09-30 · 20 participants
- Assessment of Renal Microcirculation With Rubidium Positron Emission Tomography
NCT06332456 · Phase not listed · completed · Matthieu Pelletier-Galarneau, MD MSc · started 2023-07-04 · 30 participants
Source: ClinicalTrials.gov
Recent research
- Effect of cations on van der Waals interactions between particles in aqueous alkali nitrate electrolytes.
Prange MP, Chun J, Schenter GK, et al. · Journal of colloid and interface science · 2027 Feb 15
- Longitudinally resolved temperature measurement in diode-pumped alkali lasers via dual-wavelength CH(4) absorption spectroscopy with one-step fitting.
Li M, Ye J, Wang H, et al. · Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy · 2027 Jan 15
- Modifying effects of folate, vitamin B(12) status on associations between metals exposure and mild cognitive impairment incidence: A prospective cohort study of adults living along the Yangtze River, China.
Zhong K, Yao Z, Wang W, et al. · Environmental pollution (Barking, Essex : 1987) · 2026 Dec 15
- High-Precision Rb Isotope Analysis by MC-ICP-MS Using Sr Empirical External Normalization.
Yin H, Feng Q, Li T · Rapid communications in mass spectrometry : RCM · 2026 Dec 15
- The 5(1)Π state in RbCs examined in a polarisation labelling spectroscopy experiment.
Jastrzebski W, Zhang Y, Szczepkowski J, et al. · Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy · 2026 Dec 5
Source: PubMed
Medicare Part D spending
No Medicare Part D spending reported.
Source: CMS Medicare Part D Spending by Drug
Recalls
Class II · Oct 3, 2012 · Bracco Diagnostics Inc
GMP deviation; Sr-82 levels exceeded alert limit specification
CARDIOGEN-82 (Rubidium Rb 82 Generator), 140 millicurie, Rx Only, For Elution of sterile nonpyrogenic Rubidium Chloride Rb 82, Manufactured for: Bracco Diagnostics Inc. Princeton, NJ 08543 by Medi-Physics, Inc. South Plainfield, NJ 07080, NDC 0270-0091-01
Class II · Aug 22, 2012 · Franck's Lab Inc., d.b.a. Franck's Compounding Lab
Lack of Assurance of Sterility: Franck's Lab Inc. initiated a recall of all Sterile Human Drugs distributed between 11/21/2011 and 05/21/2012. FDA environmental sampling revealed the presence of microorganisms and fungal growth in the clean room where sterile products were prepared.
RUBIDIUM 200MCG/ML INJECTABLE 30 ML (1 PRODUCT)
Source: FDA enforcement reports via openFDA