DrugHub

Ruby-Fill

Brand of rubidium

Product facts

Original applicant
Jubilant
First approved
Sep 30, 2016
Status
Marketed
Generics marketed
0

Strengths and forms

StrengthFormRouteStatusEquivalence codeApplication
N/ASOLUTIONINTRAVENOUSPrescription—NDA202153

1 of 1 listed products are currently marketed. An equivalence code starting with "A" means the FDA rates generics with the same code as substitutable.

Source: FDA Drugs@FDA / Orange Book

Boxed warning

WARNING: HIGH LEVEL RADIATION EXPOSURE WITH USE OF INCORRECT ELUENT and FAILURE TO FOLLOW THE ELUATE TESTING PROTOCOL High Level Radiation Exposure with Use of Incorrect Eluent Patients are exposed to high radiation levels when the CardioGen-82 generator is eluted with the incorrect eluent due to high strontium (Sr) 82 and Sr 85 breakthrough levels. Use only additive-free 0.9% Sodium Chloride Injection to elute the generator. If an incorrect solution is used to elute the CardioGen-82 generator: Immediately stop the patient infusion; Evaluate the patient’s radiation absorbed dose, and monitor f...

Show full text

or the effects of radiation to critical organs such as bone marrow; Permanently discontinue the use of the affected generator [see Dosage and Administration (2.5) and Warnings and Precautions (5.1) ]. Excess Radiation Exposure with Failure to Follow the Eluate Testing Protocol Excess radiation exposure occurs when the levels of Sr 82 or Sr 85 in the Rubidium Chloride Rb 82 Injection exceed specified limits. Strictly adhere to the generator eluate testing protocol, to minimize the risk of excess radiation exposure, including daily testing and additional testing at Alert Limits. Stop using the generator if it reaches any of its Expiration Limits: 17 L for the generator’s cumulative eluate volume 60 days post generator calibration date An eluate Sr 82 level of 0.01 microCi /mCi Rb 82 An eluate Sr 85 level of 0.1 microCi /mCi Rb 82 [see Dosage and Administration ( 2.5 , 2.6 , 2.7 , 2.8 ) and Warnings and Precautions ( 5.2 )] WARNING: HIGH LEVEL RADIATION EXPOSURE WITH USE OF INCORRECT ELUENT and FAILURE TO FOLLOW THE ELUATE TESTING PROTOCOL See full prescribing information for complete boxed warning. High Level Radiation Exposure with Use of Incorrect Eluent Using the incorrect eluent can cause high Strontium (Sr) 82 and Sr 85 breakthrough levels. Use only additive-free 0.9% Sodium Chloride Injection to elute CardioGen-82. If an incorrect solution is used to elute CardioGen-82: Immediately stop the patient infusion; Evaluate the patient’s radiation absorbed dose and monitor for the effects of radiation to critical organs such as bone marrow; Permanently discontinue use of the affected generator. ( 2.5 , 2.9 , 5.1 ) Excess Radiation Exposure with Failure to Follow the Eluate Testing Protocol Excess radiation exposure occurs when the levels of Sr 82 or Sr 85 in the Rubidium Chloride Rb 82 Injection exceed limits. Strictly adhere to the generator eluate testing protocol. Stop using the generator if it reaches any of its Expiration Limits. ( 2.5 , 2.6 , 2.7 , 5.2 )

What it is approved for

CardioGen-82, used to produce Rubidium Chloride Rb 82 Injection, is indicated for positron emission tomography (PET) of the myocardium under rest or pharmacologic stress conditions to evaluate regional myocardial perfusion in adult patients with suspected or existing coronary artery disease. CardioGen-82, used to produce Rubidium Chloride Rb 82 Injection, is a radioactive diagnostic agent indicated for positron emission tomography (PET) of the myocardium under rest or pharmacologic stress conditions to evaluate regional myocardial perfusion in adult patients with suspected or existing coronary...

Show full text

artery disease. ( 1 )

Full rubidium profile: trials, research, approvals →

Source: FDA label on DailyMed

Medicare Part D spending on Ruby-Fill

No Medicare Part D spending reported.

Source: CMS Medicare Part D Spending by Drug

Recalls mentioning Ruby-Fill

No recalls found in FDA enforcement reports.

Source: FDA enforcement reports via openFDA