DrugHub

Levonorgestrel: Side effects

Side effects of levonorgestrel as listed in the FDA-approved prescribing information.

Side effects in the prescribing information

Reports do not prove causation. Adverse event reports do not prove that a drug caused the event. Reports can be incomplete or duplicated, and report counts cannot be used to compare safety between drugs without knowing how many people take each one.

The following serious or otherwise important adverse reactions are discussed elsewhere in the labeling: • Ectopic Pregnancy [see Warnings and Precautions ( 5.1 )] • Intrauterine Pregnancy [see Warnings and Precautions ( 5.2 )] • Group A Streptococcal Sepsis (GAS) [see Warnings and Precautions ( 5.3 )] • Pelvic Inflammatory Disease [see Warnings and Precautions ( 5.4 )] • Perforation [see Warnings and Precautions ( 5.5 )] • Expulsion [see Warnings and Precautions ( 5.6 ] • Ovarian Cysts [see Warnings and Precautions ( 5.7 )] • Bleeding Pattern Alterations [see Warnings and Precautions ( 5.8 )] The most common adverse reactions reported (≥ 5% users) were vulvovaginitis, ovarian cysts, abdominal pain/pelvic pain, headache/migraine, acne/seborrhea, dysmenorrhea/uterine spasm, breast pain/breast discomfort, and increased bleeding. ( 6 ) To report SUSPECTED ADVERSE REACTIONS, contact Bayer HealthCare Pharmaceuticals Inc. at 1-888-842-2937 or FDA at 1-800-FDA-1088 or www.fda.gov/medwatch. 6.1 Clinical Trials Experience Because clinical trials are conducted under widely varying conditions, adverse reaction rates observed in the clinical trials of a drug cannot be directly compared to rates in the clinical trials of another drug and may not reflect the rates observed in clinical practice. The data described below reflect exposure of 1,697 healthy 18 to 41-year-old women (mean age 27.8 ± 5.2 years) to Kyleena. These data come from two multi-center contraceptive trials: A phase 2 study with a 3-year duration was conducted in Europe enrolling generally healthy, 21 to 41-year old women; 217 subjects were exposed to Kyleena for one year and 174 completed three years. The data in this trial cover approximately 8,000 cycles of exposure. A phase 3 study with a 3-year duration and an optional extension of Kyleena use up to 5 years was conducted in the United States (US), Canada, Europe, and Latin America. The population was generally healthy, 18 to 35-year old women. A total of 1,208 subjects were exposed to Kyleena for at least one year; 707 women entered the optional extension phase after 3 years and 550 completed five years. The data in this trial cover approximately 60,000 cycles. In total for both studies, 1,425 subjects were exposed for at least 1 year, and 550 subjects completed 5 years of use. Of the total of 1,697 subjects exposed to Kyleena, 563 were from the US and 1,134 were from Europe, Canada and Latin America; 623 (37%) were nulliparous (mean age 24.6 ± 4.5 years) and 1,074 (63%) were parous (mean age 29.7 ± 4.7 years). Most women who received Kyleena were Caucasian (83%) or Black/African American (4.4%); 9.4% of women were of Hispanic ethnicity. The clinical trials had no upper or lower weight or body mass index (BMI) limit. Mean BMI of Kyleena subjects was 25.2 kg/m2 (range 15.2 – 57.6 kg/m2); 16% had a BMI ≥ 30 kg/m2, and 2.0% had a BMI ≥ 40 kg/m2. The frequencies of reported adverse drug reactions represent crude incidences. The most common adve...

Show full text

rse reactions (occurring in ≥ 5% users) were vulvovaginitis (24%), ovarian cyst (22%), abdominal pain/pelvic pain (21%), headache/migraine (15%), acne/seborrhea (15%), dysmenorrhea/uterine spasm (10%), breast pain/breast discomfort (10%), and increased bleeding (8%). In the combined studies, 22% discontinued prematurely due to an adverse reaction. The most common adverse reactions (>1%) leading to discontinuation were increased bleeding (4.5%), abdominal pain/pelvic pain (4.2%), device expulsion (3.1%), acne/seborrhea (2.3%), and dysmenorrhea/uterine spasm (1.3%). Common adverse reactions (occurring in ≥1% users) are summarized in Table 4 (presented as crude incidences). Table 4: Adverse reactions that occurred in at least 1% of Kyleena users in clinical trials by System Organ Class (SOC) System Organ Class Adverse Reaction Incidence (%) (N=1,697) Reproductive System and Breast Disorders Vulvovaginitis 24.3 Ovarian cyst a 22.2 Dysmenorrhea/uterine spasm 8.0/2.4 Increased bleeding b 7.9 Breast pain/discomfort 7.1/3.5 Genital discharge 4.5 Device expulsion (complete and partial) 3.5 Upper genital tract infection 1.5 Gastrointestinal Disorders Abdominal pain/pelvic pain 13.3/8.2 Nausea 4.7 Skin and Subcutaneous Tissue Disorders Acne/Seborrhea 14.1/1.8 Alopecia 1.0 Nervous System Disorders Headache/Migraine 12.9/3.3 Psychiatric Disorders Depression/ Depressed mood 4.4/0.2 a Ovarian cysts were reported as adverse events if they were abnormal, non-functional cysts and/or had a diameter >3 cm on ultrasound examination b Not all bleeding alterations were captured as adverse reactions [see Warnings and Precautions ( 5.8 )] . In the clinical trials, serious adverse reactions occurring in more than a single subject included: ectopic pregnancy/ruptured ectopic pregnancy (10 subjects); pelvic inflammatory disease (6 subjects); missed abortion/incomplete spontaneous abortion/spontaneous abortion (4 subjects); ovarian cyst (3 subjects); abdominal pain (4 subjects); depression/affective disorder (4 subjects); and uterine perforation/embedded device (myometrial perforation) (3 subjects). 6.2 Postmarketing Experience Adverse Reactions from Postmarketing Spontaneous Reports The following adverse reactions have been identified during post-approval use of LNG-releasing IUSs. Because these reactions are reported voluntarily from a population of uncertain size, it is not always possible to reliably estimate their frequency or establish a causal relationship to drug exposure. • Arterial thrombotic and venous thromboembolic events, including cases of pulmonary embolism, deep vein thrombosis and stroke • Device breakage • Hypersensitivity (including rash, urticaria, and angioedema) • Increased blood pressure Reported Adverse Reactions from Postmarketing Studies Assessment of Perforation and Expulsion of Intrauterine Devices (APEX IUD) Study APEX IUD was a large US retrospective cohort study to assess the impact of breastfeeding and timing of postpartum IUD insertion on uterine perforation and IUD expulsion. The analyses included a total of 326,658 insertions, 30% (97,824 insertions) of which were performed in women with a delivery in the previous 12 months. For insertions performed in women who had delivered ≤ 52 weeks before IUD insertion, the majority of postpartum insertions, 57.3% (56,047 insertions) occurred between 6 and 14 weeks postpartum. Breastfeeding data were available in 94,817 insertions performed in women 52 weeks or less after delivery. The study results indicated that the risk of uterine perforation was highest in women with IUD insertion ≤ 6 weeks postpartum. Immediate postpartum insertion (0–3 days) findings are limited due to the relatively small number of insertions occurring within this time interval. Women who were breastfeeding at the time of insertion were at 33% higher risk of perforation (adjusted hazard ratio [HR]=1.33, 95% confidence interval [CI]: 1.07–1.64) compared to women who were not breastfeeding at the time of insertion. Progressively lower risk of uterine perforation was observed in postpartum time windows beyond 6 weeks, in both breastfeeding and not breastfeeding women. Table 5 presents the uterine perforation rates for LNG IUS stratified by breastfeeding status and postpartum interval. Table 5: Uterine Perforation 1 rates for LNG IUS, by Breastfeeding Status and Postpartum Interval Breastfeeding at time of insertion Not breastfeeding at time of insertion Postpartum interval at time of insertion Number of events/ insertions Uterine perforation rate per 1,000 insertions Number of events/ insertions Uterine perforation rate per 1,000 insertions 0 to 3 days 8/1,896 4.22 0/277 0.00 4 days to ≤ 6 weeks 120/10,735 11.18 28/2,377 11.78 > 6 to ≤ 14 weeks 268/29,677 9.03 80/12,011 6.66 > 14 to ≤ 52 weeks 43/6,139 7.00 22/9,089 2.42 > 52 weeks or no delivery no data available 243/184,733 1.32 1 Uterine perforation includes both complete and partial perforation Risk of expulsion was variable over the postpartum intervals through 52 weeks. Women who were breastfeeding were at 28% lower risk of IUD expulsion (adjusted HR=0.72, 95% CI: 0.64-0.80) compared to women who were not breastfeeding at time of insertion. Table 6 presents the IUD expulsion rates for LNG IUS stratified by breastfeeding status and postpartum interval. Table 6: Expulsion 1 Rates for LNG IUS, by Breastfeeding Status and Postpartum Interval Breastfeeding at time of insertion Not breastfeeding at time of insertion Postpartum interval at time of insertion Number of events/ insertions Expulsion rate per 1,000 insertions Number of events/ insertions Expulsion rate per 1,000 insertions 0 to 3 days 187/1,896 98.63 12/277 43.32 4 days to ≤ 6 weeks 185/10,735 17.23 52/2,377 21.88 > 6 to ≤ 14 weeks 421/29,677 14.19 306/12,011 25.48 > 14 to ≤ 52 weeks 120/6,139 19.55 273/9,089 30.04 > 52 weeks or no delivery no data available 5,481/184,733 29.67 1 Expulsion includes both complete and partial expulsion

Source: FDA label on DailyMed, revised Oct 23, 2025

← Back to Levonorgestrel overview