Levonorgestrel: Dosage
Dosage and administration for levonorgestrel from the FDA-approved prescribing information.
Dosage and administration
Follow the dose your prescriber gives you. This is the label text for reference.
• Release rate of levonorgestrel (LNG) is 17.5 mcg/day after 24 days and declines to 7.4 mcg/day after 5 years; Kyleena must be removed or replaced after 5 years. ( 2.1 ) • To be inserted by a trained healthcare provider using strict aseptic technique. Follow insertion instructions exactly as described. ( 2.2 ) • Patient should be re-examined and evaluated 4 to 6 weeks after insertion; then yearly or more often if clinically indicated. ( 2.3 ) 2.1 Dosing Over Time Kyleena contains 19.5 mg of levonorgestrel (LNG) released in vivo at a rate of approximately 17.5 mcg/day after 24 days. This rate decreases progressively to 9.8 mcg/day after 1 year and to 7.4 mcg/day after 5 years. The average in vivo release rate of LNG is approximately 12.6 mcg/day over the first year and 9.0 mcg/day over a period of 5 years . [See Clinical Pharmacology ( 12.3 ).] Kyleena must be removed by the end of the fifth year and can be replaced at the time of removal with a new Kyleena if continued contraceptive protection is desired. Kyleena can be physically distinguished from other intrauterine systems (IUSs) by the combination of the visibility of the silver ring on ultrasound and the blue color of the removal threads. Kyleena is supplied in a sterile package within an inserter that enables single-handed loading (see Figure 1). Do not open the package until required for insertion [see Description ( 11.2 )] . Do not use if the seal of the sterile package is broken or appears compromised. Use strict aseptic techniques throughout the insertion procedure [see Warnings and Precautions ( 5.3 )] . Kyleena and Inserter 2.2. Insertion Instructions • Obtain a complete medical and social history to determine conditions that might influence the selection of a levonorgestrel-releasing intrauterine system (LNG IUS) for contraception . If indicated, perform a physical examination and appropriate tests for any forms of genital or other sexually transmitted infections. [See Contraindications ( 4 ) and Warnings and Precautions ( 5.10 ).] Because irregular bleeding/spotting is common during the first months of Kyleena use, exclude endometrial pathology (polyps or cancer) prior to the insertion of Kyleena in women with persistent or uncharacteristic bleeding [see Warnings and Precautions ( 5.8 )] . • Follow the insertion instructions exactly as described to ensure proper placement and avoid premature release of Kyleena from the inserter. Once released, Kyleena cannot be re-loaded . • Check expiration date of Kyleena prior to initiating insertion. • Kyleena should be inserted by a trained healthcare provider. Healthcare providers should become thoroughly familiar with the insertion instructions before attempting insertion of Kyleena. • Insertion may be associated with some pain and/or bleeding or vasovagal reactions (for example, syncope, bradycardia), or with seizure, especially in patients with a predisposition to these conditions. Consider administering analgesics prior to insertion. Timi...
Show full text
ng of Insertion Table 1: When to Insert Kyleena Starting Kyleena in women not currently using hormonal or intrauterine contraception • Insert Kyleena any time there is reasonable certainty that the woman is not pregnant. Consider the possibility of ovulation and conception prior to initiation of this product [see Contraindications ( 4 )]. • If Kyleena is inserted during the first seven days of the menstrual cycle or immediately after a first trimester abortion, back-up contraception is not needed. • If Kyleena is not inserted during the first seven days of the menstrual cycle, a barrier method of contraception should be used, or the patient should abstain from vaginal intercourse for seven days to prevent pregnancy. Switching to Kyleena from an oral, transdermal or vaginal hormonal contraceptive • Insert Kyleena at any time, including during the hormone-free interval of the previous method. • If inserted during active use of the previous method, continue that method for 7 days after Kyleena insertion or until the end of the current treatment cycle. • If the woman was using continuous hormonal contraception, discontinue that method seven days after Kyleena insertion. Switching to Kyleena from an injectable progestin contraceptive • Insert Kyleena at any time; a non-hormonal back-up birth control (such as condoms or spermicide) should also be used for 7 days if Kyleena is inserted more than 3 months (13 weeks) after the last injection. Switching to Kyleena from a contraceptive implant or another IUS • Insert Kyleena on the same day the implant or IUS is removed. • Insert Kyleena at any time during the menstrual cycle. Inserting Kyleena after first trimester abortion or miscarriage • Insert Kyleena immediately after a first-trimester abortion or miscarriage, unless it is a septic abortion [see Contraindications ( 4 )]. Inserting Kyleena after childbirth or second-trimester abortion or miscarriage • Immediate insertion after childbirth or second-trimester abortion or miscarriage • Insert Kyleena after removal of the placenta. Back-up contraception is not needed. [See Contraindications ( 4 ), Warnings and Precautions ( 5.5 , 5.6 ), Adverse Reactions ( 6.2 )]. Interval insertion following complete involution of the uterus • Wait a minimum of 6 weeks or until the uterus is fully involuted before inserting Kyleena [see Warnings and Precautions ( 5.5 , 5.6) , Adverse Reactions ( 6.2 )]. • Insert Kyleena any time there is reasonable certainty the woman is not pregnant. • If Kyleena is not inserted during the first 7 days of the menstrual cycle, a back-up method of contraception should be used, or the woman should abstain from vaginal intercourse for 7 days to prevent pregnancy [see Contraindications ( 4 ), Warnings and Precautions ( 5.2 )]. Tools for Insertion Note: The inserter provided with Kyleena (see Figure 1) and the Insertion Procedure described in this section are not applicable for immediate insertion after childbirth or second-trimester abortion or miscarriage. For immediate insertion, remove Kyleena from the inserter by first loading (see Figure 2) and then releasing (see Figure 7) Kyleena from the inserter, and insert according to accepted practice. Preparation • Gloves • Speculum • Sterile uterine sound • Sterile tenaculum • Antiseptic solution, applicator Procedure • Sterile gloves • Kyleena with inserter in sealed package • Instruments and anesthesia for paracervical block, if anticipated • Consider having an unopened back-up Kyleena available • Sterile, sharp curved scissors Preparation for insertion • Exclude pregnancy and confirm that there are no other contraindications to the use of Kyleena. • With the patient comfortably in lithotomy position, do a bimanual exam to establish the size, shape and position of the uterus. • Gently insert a speculum to visualize the cervix. • Thoroughly cleanse the cervix and vagina with a suitable antiseptic solution. • Prepare to sound the uterine cavity. Grasp the upper lip of the cervix with a tenaculum forceps and gently apply traction to stabilize and align the cervical canal with the uterine cavity. Perform a paracervical block if needed. If the uterus is retroverted, it may be more appropriate to grasp the lower lip of the cervix. The tenaculum should remain in position and gentle traction on the cervix should be maintained throughout the insertion procedure. • Gently insert a uterine sound to check the patency of the cervix, measure the depth of the uterine cavity in centimeters, confirm cavity direction, and detect the presence of any uterine anomaly. If you encounter difficulty or cervical stenosis, use dilatation, and not force, to overcome resistance. If cervical dilatation is required, consider using a paracervical block. Insertion Procedure Proceed with insertion only after completing the above steps and ascertaining that the patient is appropriate for Kyleena. Ensure use of aseptic technique throughout the entire procedure . Step 1–Opening of the package • Open the package (Figure 1). The contents of the package are sterile. Figure 1. Opening the Kyleena Package • Using sterile gloves, lift the handle of the sterile inserter and remove from the sterile package. Package Step 2–Load Kyleena into the insertion tube • Push the slider forward as far as possible in the direction of the arrow, thereby moving the insertion tube over the Kyleena T-body to load Kyleena into the insertion tube (Figure 2). The tips of the arms will meet to form a rounded end that extends slightly beyond the insertion tube. Figure 2. Move slider all the way to the forward position to load Kyleena • Maintain forward pressure with your thumb or forefinger on the slider . DO NOT move the slider downward at this time as this may prematurely release the threads of Kyleena. Once the slider is moved below the mark, Kyleena cannot be re-loaded . Load Kyleena Step 3–Setting the Flange • Holding the slider in this forward position, set the upper edge of the flange to correspond to the uterine depth (in centimeters) measured during sounding (Figure 3). Figure 3. Setting the flange Setting Flange Step 4–Kyleena is now ready to be inserted • Continue holding the slider in this forward position. Advance the inserter through the cervix until the flange is approximately 1.5–2 cm from the cervix and then pause (Figure 4). Figure 4. Advancing insertion tube until flange is 1.5 to 2 cm from the cervix Do not force the inserter. If necessary, dilate the cervical canal. Advancing Flange Step 5–Open the arms • While holding the inserter steady, move the slider down to the mark to release the arms of Kyleena (Figure 5). Wait 10 seconds for the horizontal arms to open completely. Figure 5. Move the slider back to the mark to release and open the arms Back to Mark Step 6–Advance to fundal position Advance the inserter gently towards the fundus of the uterus until the flange touches the cervix . If you encounter fundal resistance do not continue to advance. Kyleena is now in the fundal position (Figure 6). Fundal positioning of Kyleena is important to prevent expulsion . Figure 6. Move Kyleena into the fundal position Funda Position Step 7–Release Kyleena and withdraw the inserter • Holding the entire inserter firmly in place, release Kyleena by moving the slider all the way down (Figure 7). Figure 7. Move the slider all the way down to release Kyleena from the insertion tube • Continue to hold the slider all the way down while you slowly and gently withdraw the inserter from the uterus. • Using a sharp, curved scissor, cut the threads perpendicular, leaving about 3 cm visible outside of the cervix [cutting threads at an angle may leave sharp ends (Figure 8)]. Do not apply tension or pull on the threads when cutting to prevent displacing Kyleena. Figure 8. Cutting the threads Kyleena insertion is now complete. Prescribe analgesics, if indicated. Record the Kyleena lot number in the patient records. Moving Slider Cutting Threads Important information to consider during or after insertion • If you suspect that Kyleena is not in the correct position, check placement (for example, using transvaginal ultrasound). Remove Kyleena if it is not positioned completely within the uterus. Do not reinsert a removed Kyleena. • If there is clinical concern, exceptional pain or bleeding during or after insertion, take appropriate steps (such as physical examination and ultrasound) immediately to exclude perforation. 2.3 Patient Follow-up • Reexamine and evaluate patients 4 to 6 weeks after insertion and once a year thereafter, or more frequently if clinically indicated. 2.4 Removal of Kyleena Timing of Removal • Kyleena should not remain in the uterus after 5 years. • If pregnancy is not desired, remove Kyleena during the first 7 days of the menstrual cycle, provided the woman is still experiencing regular menses. If removal will occur at other times during the cycle or the woman does not experience regular menses, she is at risk of pregnancy; s
Source: FDA label on DailyMed, revised Oct 23, 2025