Isatuximab: Drug interactions
Drug interactions for isatuximab from the FDA-approved prescribing information.
Drug interactions
7.1 Laboratory Test Interference Interference with Serological Testing Isatuximab-irfc, an anti-CD38 antibody, may interfere with blood bank serologic tests with false positive reactions in indirect antiglobulin tests (indirect Coombs tests), antibody detection (screening) tests, antibody identification panels, and antihuman globulin crossmatches in patients treated with isatuximab-irfc [see Warnings and Precautions (5.5) ] . Interference with Serum Protein Electrophoresis and Immunofixation Tests Isatuximab-irfc may be incidentally detected by serum protein electrophoresis and immunofixation assays used for the monitoring of M-protein and may interfere with accurate response classification based on International Myeloma Working Group (IMWG) criteria [see Warnings and Precautions (5.5) ] . Because of this interference, Hydrashift assay was routinely used in IRAKLIA and IZALCO clinical studies for efficacy assessment to determine the complete response in patients with IgG kappa myeloma protein. In patients with persistent very good partial response, where interference is suspected, consider using an FDA-cleared isatuximab-irfc-specific IFE assay to distinguish isatuximab-irfc from any remaining endogenous M-protein in the patient's serum to facilitate determination of a complete response.
Source: FDA label on DailyMed, revised Jul 10, 2026