DrugHub

Ioversol (Optiray)

Active ingredient · RxNorm 27792 · Data updated Nov 29, 2026

Brand names

About ioversol

Ioversol, marketed under the brand name Optiray, is a radiographic contrast agent first approved by the FDA on December 30, 1988 [1][2]. It functions by opacifying blood vessels and internal structures to improve visibility during imaging procedures until the contrast medium is diluted by the bloodstream [1]. It is used in various intra-arterial procedures, such as arteriography and angiocardiography, as well as intravenous procedures, including CT imaging, venography, and excretory urography [1]. The product label includes a boxed warning stating that it is not for intrathecal use, as accidental administration into the spinal canal can lead to severe complications, including death, paralysis, and seizures [1]. Currently, there are no generic or biosimilar versions of ioversol marketed [2]. Research regarding this agent is extensive, with approximately 337 articles indexed in PubMed and 19 clinical studies listed on ClinicalTrials.gov [3][4]. Additionally, FDA enforcement reports have documented two product recalls involving ioversol, one of which was classified as Class I [5].

  1. [1] FDA drug label (DailyMed)
  2. [2] FDA Drugs@FDA / Orange Book
  3. [3] ClinicalTrials.gov
  4. [4] PubMed
  5. [5] FDA enforcement reports (openFDA)

Summary written by an AI model (google/gemini-2.5-flash-lite) from the cited public records, 11/29/2026. Check the sources before relying on it.

Key facts

First FDA approval
Dec 30, 1988

37 years on market

Brand applications
2
Generic applications
0

Competition: none (0 marketed)

Application holders
1
Clinical trials
19

3 recruiting now

PubMed articles
337
Medicare spend
Not reported
Recalls
2

1 Class I

Counts are calculated from FDA, ClinicalTrials.gov, PubMed and CMS records.

Boxed warning

WARNING: NOT FOR INTRATHECAL USE Inadvertent intrathecal administration may cause death, convulsions, cerebral hemorrhage, coma, paralysis, arachnoiditis, acute renal failure, cardiac arrest, seizures, rhabdomyolysis, hyperthermia, and brain edema [see Warnings and Precautions ( 5.1 )]. WARNING: NOT FOR INTRATHECAL USE See full prescribing information for complete boxed warning . Inadvertent intrathecal administration may cause death, convulsion, cerebral hemorrhage, coma, paralysis, arachnoiditis, acute renal failure, cardiac arrest, seizures, rhabdomyolysis, hyperthermia, and brain edema [se...

Show full text

e Warnings and Precautions ( 5.1 )].

What it is approved for

is indicated for: OPTIRAY is a radiographic contrast agent indicated for the following: Intra-arterial Procedures ( 1.1 ) Adults: Cerebral Arteriography (320 mg iodine/mL) Peripheral Arteriography (320, 350 mg iodine/mL ) Visceral and Renal Arteriography, Aortography (320 mg iodine/mL) Coronary Arteriography and Left Ventriculography (320, 350 mg iodine/mL) Pediatric Patients: Angiocardiography (320, 350 mg iodine/mL) Intravenous Procedures ( 1.2 ) Adults: Computed tomography (CT) Imaging of Head and Body (320, 350 mg iodine/mL) Venography (320, 350 mg iodine/mL) Intravenous Excretory Urography (320, 350 mg iodine/mL) Intravenous Digital Subtraction Angiography (350 mg iodine/mL) Pediatric Patients: CT Imaging of the Head and Body, and Intravenous Excretory Urography (320mg iodine/mL). 1.1 Intra-arterial In adults OPTIRAY 320: cerebral arteriography, peripheral arteriography, visceral an...

Show full text

d renal arteriography, aortography, coronary arteriography, and left ventriculography. OPTIRAY 350: peripheral arteriography, coronary arteriography, and left ventriculography. In pediatric patients OPTIRAY 320 and OPTIRAY 350: angiocardiography. 1.2 Intra-venous In adults OPTIRAY 320: CT imaging of the head and body, venography, and intravenous excretory urography. OPTIRAY 350: CT imaging of the head and body, venography, intravenous excretory urography, and intravenous digital subtraction angiography (IV-DSA). In pediatric patients OPTIRAY 320: CT imaging of the head and body, and intravenous excretory urography.

Source: FDA label on DailyMed, revised Dec 29, 2025

How it works

12.1 Mechanism of Action Intravascular injection of ioversol opacifies those vessels in the path of the flow of the contrast medium, permitting radiographic visualization of the internal structures until significant hemodilution occurs. Ioversol may be visualized in the renal parenchyma within 30 to 60 seconds following rapid intravenous injection. Opacification of the calyces and pelves in patients with normal renal function becomes apparent within 1 to 3 minutes, with optimum contrast occurring within 5 to 15 minutes. OPTIRAY enhances computed tomographic imaging through augmentation of radi...

Show full text

ographic efficiency. The degree of density enhancement is directly related to the iodine content in an administered dose; peak iodine blood levels occur immediately following rapid intravenous injection. Blood levels fall rapidly within 5 to 10 minutes and the vascular compartment half-life is approximately 20 minutes. This can be accounted for by the dilution in the vascular and extravascular fluid compartments which causes an initial sharp fall in plasma concentration. Equilibration with the extracellular compartments is reached in about 10 minutes; thereafter, the fall becomes exponential.

Source: FDA label on DailyMed, revised Dec 29, 2025

FDA approvals, generics and biosimilars

ApplicationTypeHolderApprovedProductsStatus
NDA019710Brand (NDA)Liebel-FlarsheimDec 30, 1988OPTIRAY (5)Marketed
NDA020923Brand (NDA)Liebel-FlarsheimMay 29, 1998OPTIRAY (4)Marketed

Source: FDA Drugs@FDA / Orange Book, Purple Book

Clinical trials

See all: Clinical trials →

Source: ClinicalTrials.gov

Recent research

See all: Research →

Source: PubMed

Medicare Part D spending

No Medicare Part D spending reported.

Source: CMS Medicare Part D Spending by Drug

Recalls

  • Class I · Aug 19, 2026 · Liebel-Flarsheim Company LLC

    Presence of Particulate Matter: comprising polyethylene and other plastic materials, stainless steel and glass.

    Optiray Imaging Bulk Package-350, Ioversol Injection 74%, 350 mg/mL Organically Bound Iodine, 500 mL Multiple-Dose Vial, Rx only, Sterile Solution, Manufactured by: Liebel-Flarsheim Company LLC, Raleigh, NC 27616, Made in USA, NDC 0019-1333-65.

  • Class II · Oct 16, 2019 · GUERBET LLC

    Labeling: Not Elsewhere Classified: RFID formatting error which reads product in Ultraject syringe as expired and will not allow injection of product by the Optivantage injector.

    Optiray 320 (ioversol) Injection 68%, 320 mg/mL Organically Bound Iodine, packaged in 1 - 100 mL Ultraject Prefilled Syringe For Power Injection per carton, RFID Technology, Rx Only, Manufactured by: Liebel-Flarshelm Company, LLC., Raleigh, NC 27616; NDC 0019-1323-00.

See all: Recalls →

Source: FDA enforcement reports via openFDA