Gadodiamide (Omniscan)
Active ingredient · RxNorm 41144 · Data updated Nov 29, 2026
Brand names
About gadodiamide
Gadodiamide, marketed under the brand name Omniscan, is a gadolinium-based contrast agent used during magnetic resonance imaging (MRI) [1][2]. First approved by the FDA in 1993, it is administered intravenously to help visualize lesions with abnormal vascularity in the brain, spine, and associated tissues [1][2]. Additionally, it is used to assist in viewing lesions within the thoracic, abdominal, pelvic, and retroperitoneal regions [1]. The drug label includes a boxed warning regarding the risk of nephrogenic systemic fibrosis and notes that the agent is not approved for intrathecal use, as such administration can lead to severe adverse reactions, including death, coma, seizures, and encephalopathy [1]. Research regarding this agent is extensive, with approximately 720 articles indexed in PubMed and 10 studies listed on ClinicalTrials.gov, one of which is currently recruiting participants [3][4].
Summary written by an AI model (google/gemini-2.5-flash-lite) from the cited public records, 11/29/2026. Check the sources before relying on it.
Key facts
- First FDA approval
- Jan 8, 1993
- Brand applications
- 2
- Generic applications
- 0
- Application holders
- 1
- Clinical trials
- 10
- PubMed articles
- 720
- Medicare spend
- Not reported
- Recalls
- 0
33 years on market
Competition: none (0 marketed)
1 recruiting now
0 Class I
Counts are calculated from FDA, ClinicalTrials.gov, PubMed and CMS records.
Boxed warning
WARNING: RISK ASSOCIATED WITH INTRATHECAL USE and NEPHROGENIC SYSTEMIC FIBROSIS WARNING: RISK ASSOCIATED WITH INTRATHECAL USE and NEPHROGENIC SYSTEMIC FIBROSIS See full prescribing information for complete boxed warning. Intrathecal administration of gadolinium-based contrast agents (GBCAs) can cause serious adverse reactions including death, coma, encephalopathy, and seizures. OMNISCAN is not approved for intrathecal use ( 5.1 ). GBCAs increase the risk for nephrogenic systemic fibrosis among patients with impaired elimination of the drugs. Avoid use of OMNISCAN in these patients unless the d...
Show full text
iagnostic information is essential and not available with non-contrasted MRI or other modalities. Do not administer OMNISCAN to patients with: chronic, severe kidney disease (GFR < 30 mL/min/1.73m 2 ), or acute kidney injury ( 4 ). Screen patients for acute kidney injury and other conditions that may reduce renal function. For patients at risk for chronically reduced renal function (e.g., age > 60 years, hypertension or diabetes), estimate the glomerular filtration rate (GFR) through laboratory testing ( 5.2 ). Risk Associated with Intrathecal Use Intrathecal administration of gadolinium-based contrast agents (GBCAs) can cause serious adverse reactions including death, coma, encephalopathy, and seizures. OMNISCAN is not approved for intrathecal use [see Warnings and Precautions (5.1) ]. Nephrogenic Systemic Fibrosis GBCAs increase the risk for nephrogenic systemic fibrosis (NSF) among patients with impaired elimination of the drugs. Avoid use of OMNISCAN in these patients unless the diagnostic information is essential and not available with non-contrasted MRI or other modalities. NSF may result in fatal or debilitating fibrosis affecting the skin, muscle and internal organs. Do not administer OMNISCAN to patients with: chronic, severe kidney disease (GFR < 30 mL/min/1.73m 2 ), or acute kidney injury [see Contraindications (4) ]. Screen patients for acute kidney injury and other conditions that may reduce renal function. For patients at risk for chronically reduced renal function (e.g., age > 60 years, hypertension or diabetes), estimate the glomerular filtration rate (GFR) through laboratory testing. Do not exceed the recommended OMNISCAN dose and allow a sufficient period of time for elimination of the drug from the body prior to any readministration [see Warnings and Precautions (5.2) ].
What it is approved for
is a gadolinium-based contrast agent for diagnostic magnetic resonance imaging (MRI) indicated for intravenous use to: Visualize lesions with abnormal vascularity in the brain, spine, and associated tissues ( 1.1 ) Facilitate the visualization of lesions with abnormal vascularity within the thoracic, abdominal, pelvic cavities, and the retroperitoneal space ( 1.2 ) 1.1 CNS (Central Nervous System) OMNISCAN is a gadolinium-based contrast agent indicated for intravenous use in MRI to visualize lesions with abnormal vascularity (or those thought to cause abnormalities in the blood-brain barrier) in the brain (intracranial lesions), spine, and associated tissues [see Clinical Studies (14.1) ]. 1.2 Body (Intrathoracic [noncardiac], Intra-abdominal, Pelvic and Retroperitoneal Regions) OMNISCAN is a gadolinium-based contrast agent indicated for intravenous use in MRI to facilitate the visualiza...
Show full text
tion of lesions with abnormal vascularity within the thoracic (noncardiac), abdominal, pelvic cavities, and the retroperitoneal space [see Clinical Studies (14.2) ].
Source: FDA label on DailyMed, revised Apr 18, 2025
FDA approvals, generics and biosimilars
| Application | Type | Holder | Approved | Products | Status |
|---|---|---|---|---|---|
| NDA020123 | Brand (NDA) | Ge Healthcare | Jan 8, 1993 | OMNISCAN (1) | Marketed |
| NDA022066 | Brand (NDA) | Ge Healthcare | Sep 5, 2007 | OMNISCAN (2) | Discontinued |
Source: FDA Drugs@FDA / Orange Book, Purple Book
Clinical trials
- Non-Contrast Versus Contrast-Enhanced MRI in Colorectal Liver Metastases
NCT07857317 · Phase not listed · not yet recruiting · Assiut University · started 2026-09-27 · 40 participants
- Effect on Body Movement and Mental Skills in Patients Who Received Gadolinium-based Contrast Media for Magnetic Resonance Examination Multiple Times Within 5 Years
NCT04373564 · Phase 4 · recruiting · Guerbet · started 2021-03-24 · 2,076 participants
- Safety Evaluation of Linear and Macrocyclic Gadolinium Based Contrast Agents for Patients With Mild to Moderate Renal Insufficiency Undergoing Enhanced Magnetic Resonance Imaging
NCT04776187 · Phase 4 · unknown · The Central Hospital of Lishui City · started 2021-03-01 · 600 participants
- Transrectal MRI-Guided Biopsy in Identifying Cancer in Patients With Suspected Prostate Cancer
NCT02501759 · Not applicable · terminated · OHSU Knight Cancer Institute · started 2015-05 · 2 participants
- Post-marketing Safety Study in Patients With Moderate Renal Insufficiency Who Receive Omniscan for Contrast-enhanced Magnetic Resonance Imaging (MRI)
NCT00908310 · Phase 4 · completed · GE Healthcare · started 2009-05 · 213 participants
Source: ClinicalTrials.gov
Recent research
- Tungsten disulfide-zeolitic imidazolate framework-8 nanoplatform loaded with gadolinium and conjugated with folic acid-PEG for bimodal CT/MRI imaging and 15 MV X-ray radiosensitization of glioblastoma and prostate cancer cells.
Almudaimeegh L, Hamd ZY, Alharbi M, et al. · Methods (San Diego, Calif.) · 2026 Dec
- Effect of liver fibrosis on gadolinium retention from gadodiamide, gadobutrol, and gadoxetate disodium in rats.
Kim HC, Oh H, Kim HM, et al. · Japanese journal of radiology · 2026 Sep
- Dentate nucleus signal changes after multiple GBCAs MRI in breast cancer patients: A generalized additive model retrospective study.
Wang C, Jiang Y, Liu M, et al. · Magnetic resonance imaging · 2026 Sep
- Deep Venous Perivascular Space Dysfunction Reflects Glymphatic Aging and Predicts Cognitive Vulnerability: In Vivo Human Evidence.
Zhang K, Zhou Y, Li Y, et al. · Aging and disease · 2026 May 15
- RETRACTION: Bivalent Gadolinium Ions Forming Injectable Hydrogels for Simultaneous In Situ Vaccination Therapy and Imaging of Soft Tissue Sarcoma.
Advanced healthcare materials · 2026 May
Source: PubMed
Medicare Part D spending
No Medicare Part D spending reported.
Source: CMS Medicare Part D Spending by Drug
Recalls
No recalls found in FDA enforcement reports.
Source: FDA enforcement reports via openFDA