Gadobutrol (Gadavist)
Active ingredient · RxNorm 84990 · Data updated Nov 29, 2026
Brand names
About gadobutrol
Gadobutrol, first approved by the FDA in 2011, is a gadolinium-based contrast agent used to enhance magnetic resonance imaging (MRI) and angiography [1][2]. Known by brand names such as Gadavist, it works by altering the magnetic properties of water protons in the body, which increases the brightness of tissues during scans [1][2]. It is indicated for imaging the central nervous system, breasts, and arteries, as well as for cardiac perfusion assessments in various patient populations, including neonates [1]. The medication carries a boxed warning regarding the risk of nephrogenic systemic fibrosis in patients with impaired kidney function and notes that it is not approved for intrathecal use, which can cause severe adverse reactions [1]. There are currently six generic versions of the drug marketed [2]. Extensive research supports this agent, with 116 studies listed on ClinicalTrials.gov and approximately 734 articles indexed in PubMed [3][4].
Summary written by an AI model (google/gemini-2.5-flash-lite) from the cited public records, 11/29/2026. Check the sources before relying on it.
Key facts
- First FDA approval
- Mar 14, 2011
- Brand applications
- 1
- Generic applications
- 6
- Application holders
- 6
- Clinical trials
- 116
- PubMed articles
- 734
- Medicare spend
- Not reported
- Recalls
- 0
15 years on market
Competition: moderate (6 marketed)
15 recruiting now
0 Class I
Counts are calculated from FDA, ClinicalTrials.gov, PubMed and CMS records.
Boxed warning
WARNING: RISK ASSOCIATED WITH INTRATHECAL USE and NEPHROGENIC SYSTEMIC FIBROSIS Risk Associated with Intrathecal Use Intrathecal administration of gadolinium-based contrast agents (GBCAs) can cause serious adverse reactions including death, coma, encephalopathy, and seizures. Pixxoscan is not approved for intrathecal use [see Warnings and Precautions (5.1) ]. Nephrogenic Systemic Fibrosis GBCAs increase the risk for nephrogenic systemic fibrosis (NSF) among patients with impaired elimination of the drugs. Avoid use of Pixxoscan in these patients unless the diagnostic information is essential a...
Show full text
nd not available with non-contrasted MRI or other modalities. NSF may result in fatal or debilitating fibrosis affecting the skin, muscle and internal organs. The risk for NSF appears highest among patients with: Chronic, severe kidney disease (GFR < 30 mL/min/1.73m 2 ), or Acute kidney injury. Screen patients for acute kidney injury and other conditions that may reduce renal function. For patients at risk for chronically reduced renal function (for example, age > 60 years, hypertension or diabetes), estimate the glomerular filtration rate (GFR) through laboratory testing. For patients at highest risk for NSF, do not exceed the recommended Pixxoscan dose and allow a sufficient period of time for elimination of the drug from the body prior to any re-administration [see Warnings and Precautions (5.2) ]. WARNING: RISK ASSOCIATED WITH INTRATHECAL USE and NEPHROGENIC SYSTEMIC FIBROSIS See full prescribing information for complete boxed warning. Intrathecal administration of gadolinium-based contrast agents (GBCAs) can cause serious adverse reactions including death, coma, encephalopathy, and seizures. Pixxoscan is not approved for intrathecal use. ( 5.1 ) GBCAs increase the risk for nephrogenic systemic fibrosis (NSF) among patients with impaired elimination of the drugs. Avoid use of Pixxoscan in these patients unless the diagnostic information is essential and not available with non-contrasted MRI or other modalities. The risk for NSF appears highest among patients with: Chronic, severe kidney disease (GFR < 30 mL/min/1.73m 2 ), or Acute kidney injury. Screen patients for acute kidney injury and other conditions that may reduce renal function. For patients at risk for chronically reduced renal function (for example, age >60 years, hypertension or diabetes), estimate the glomerular filtration rate (GFR) through laboratory testing. ( 5.2 )
What it is approved for
Pixxoscan is indicated for: Magnetic resonance imaging (MRI) of the central nervous system (CNS) to detect and visualize areas with disrupted blood brain barrier and/or abnormal vascularity in adult and pediatric patients including term neonates MRI of the breast to assess the presence and extent of malignant breast disease in adult patients Magnetic resonance angiography (MRA) to evaluate known or suspected supra-aortic or renal artery disease in adult and pediatric patients including term neonates Cardiac MRI (CMRI) to assess myocardial perfusion (stress, rest) and late gadolinium enhancement in adult patients with known or suspected coronary artery disease (CAD) Pixxoscan is a gadolinium-based contrast agent indicated for use with magnetic resonance imaging (MRI): To detect and visualize areas with disrupted blood brain barrier and/or abnormal vascularity of the central nervous system...
Show full text
in adult and pediatric patients including term neonates To assess the presence and extent of malignant breast disease in adult patients To evaluate known or suspected supra-aortic or renal artery disease in adult and pediatric patients including term neonates To assess myocardial perfusion (stress, rest) and late gadolinium enhancement in adult patients with known or suspected coronary artery disease (CAD) ( 1 )
Source: FDA label on DailyMed, revised Oct 9, 2026
How it works
12.1 Mechanism of Action Gadobutrol is a paramagnetic molecule (macrocyclic non-ionic complex of gadolinium) that develops a magnetic moment when placed in a magnetic field. The magnetic moment alters the relaxation rates of water protons in its vicinity in the body, leading to an increase in signal intensity (brightness) of tissues.
Source: FDA label on DailyMed, revised Oct 9, 2026
FDA approvals, generics and biosimilars
| Application | Type | Holder | Approved | Products | Status |
|---|---|---|---|---|---|
| NDA201277 | Brand (NDA) | Bayer Hlthcare | Mar 14, 2011 | GADAVIST (6) | Marketed |
| ANDA215061 | Generic (ANDA) | Hengrui Pharma | Nov 17, 2022 | GADOBUTROL (4) | Marketed |
| ANDA217480 | Generic (ANDA) | Hainan Poly Pharm | Mar 15, 2023 | GADOBUTROL (6) | Marketed |
| ANDA216081 | Generic (ANDA) | Hengrui Pharma | Sep 8, 2023 | GADOBUTROL (6) | Marketed |
| ANDA219146 | Generic (ANDA) | Zenara | Jun 8, 2026 | GADOBUTROL (6) | Marketed |
| ANDA219287 | Generic (ANDA) | Viwit Pharm | Jun 11, 2026 | GADOBUTROL (3) | Marketed |
| ANDA215957 | Generic (ANDA) | Ge Hlthcare | Jun 29, 2026 | PIXXOSCAN (4) | Marketed |
Source: FDA Drugs@FDA / Orange Book, Purple Book
Clinical trials
- Dynamic Magnetic Resonance Imaging of Human Subarachnoid Space Using Intrathecal Gadolinium Contrast
NCT07796360 · Phase 1 · recruiting · National Institute of Neurological Disorders and Stroke (NINDS) · started 2026-12-01 · 15 participants
- RCT to Compare Stress-CMR Using Mobile MRI vs. MRI for Inpatients
NCT06246188 · Phase not listed · recruiting · German Heart Institute · started 2026-11-09 · 250 participants
- Impact of Continuous Positive Airway Pressure Therapy on Bilateral Local Hippocampal Gray Matter Volume in Elderly Patients With Obstructive Sleep Apnea - Study BBBSAS
NCT07882433 · Not applicable · not yet recruiting · Centre Hospitalier Universitaire de Saint Etienne · started 2026-11-01 · 50 participants
- Optimizing Contrast Dose and Scanning Parameters for Detection of Leptomeningeal Disease
NCT07415018 · Not applicable · recruiting · M.D. Anderson Cancer Center · started 2026-06-10 · 40 participants
- Quantitative Analysis of Cardiac Muscle Perfusion
NCT07548879 · Not applicable · not yet recruiting · St. Anne's University Hospital Brno, Czech Republic · started 2026-06-01 · 35 participants
Source: ClinicalTrials.gov
Recent research
- The Impact of Water Exchange on Estimates of Myocardial Blood Flow and Extracellular Volume Fraction Using Dynamic Contrast-Enhanced MRI in Patients Treated for Severe Aortic Stenosis.
Makins A, Biglands JD, Sharrack N, et al. · Magnetic resonance in medicine · 2027 Jan
- Efficacy of a Novel Dimeric Macrocyclic Gadolinium Chelate With High Relaxivity in Preclinical Models of Neurological and Oncological Pathologies.
La Cava F, Colombo Serra S, Cordaro A, et al. · Investigative radiology · 2026 Dec 1
- From MRI Contrast to Compatibility: Distinct Macrophage and Neutrophil Responses to Metal Oxide Nanoparticles versus Gadobutrol.
Panchal DM, Dese K, Alkhadrawi H, et al. · ACS omega · 2026 Nov 24
- Half-Dose Gadopiclenol versus Full-Dose Gadobutrol for Hydrops MR Imaging: Comparison in Contralateral Clinically Unaffected Ears.
Bernaerts A, Wuyts F, Blaivie C, et al. · AJNR. American journal of neuroradiology · 2026 Nov 17
- Comparative incidence and severity of iodinated and gadolinium-based contrast reactions using actual administration counts: A five-year single-center study.
Kang SI, Kang CH, Lee KB · Clinical imaging · 2026 Nov 6
Source: PubMed
Medicare Part D spending
No Medicare Part D spending reported.
Source: CMS Medicare Part D Spending by Drug
Recalls
No recalls found in FDA enforcement reports.
Source: FDA enforcement reports via openFDA