Gadobenate (Multihance)
Active ingredient · RxNorm 692620 · Data updated Nov 29, 2026
Brand names
About gadobenate
Gadobenate, first approved by the FDA in 2004, is a paramagnetic contrast agent used to enhance the brightness of tissues during magnetic resonance imaging (MRI) and magnetic resonance angiography (MRA) [1][2]. It is indicated for MRI of the central nervous system in adults and children, including term neonates, to help visualize lesions in the brain and spine [1]. Additionally, it is used in MRA to evaluate adults with known or suspected vascular disease in the renal or aorto-ilio-femoral regions [1]. The agent works by creating a magnetic moment that increases the signal intensity of water protons in nearby tissue [1]. The product label includes a boxed warning regarding the risk of nephrogenic systemic fibrosis in patients with impaired kidney function and a warning against intrathecal use, which can cause serious reactions like seizures or death [1]. Marketed under the brand name MultiHance, the drug is the subject of over 700 scientific articles and 24 clinical studies [1][2][3][4]. There have been two FDA-reported recalls of products containing gadobenate, neither of which were Class I [5].
- [1] FDA drug label (DailyMed)
- [2] FDA Drugs@FDA / Orange Book
- [3] ClinicalTrials.gov
- [4] PubMed
- [5] FDA enforcement reports (openFDA)
Summary written by an AI model (google/gemini-2.5-flash-lite) from the cited public records, 11/29/2026. Check the sources before relying on it.
Key facts
- First FDA approval
- Nov 23, 2004
- Brand applications
- 2
- Generic applications
- 0
- Application holders
- 1
- Clinical trials
- 24
- PubMed articles
- 709
- Medicare spend
- Not reported
- Recalls
- 2
22 years on market
Competition: none (0 marketed)
2 recruiting now
0 Class I
Counts are calculated from FDA, ClinicalTrials.gov, PubMed and CMS records.
Boxed warning
WARNING: RISK ASSOCIATED WITH INTRATHECAL USE and NEPHROGENIC SYSTEMIC FIBROSIS Risk Associated with Intrathecal Use Intrathecal administration of gadolinium-based contrast agents (GBCAs) can cause serious adverse reactions including death, coma, encephalopathy, and seizures. MultiHance is not approved for intrathecal use [see Warnings and Precautions (5.1) ] . Nephrogenic Systemic Fibrosis GBCAs increase the risk for nephrogenic systemic fibrosis (NSF) among patients with impaired elimination of the drugs. Avoid use of MultiHance in these patients unless the diagnostic information is essentia...
Show full text
l and not available with non-contrasted MRI or other modalities. NSF may result in fatal or debilitating systemic fibrosis affecting the skin, muscle and internal organs. The risk for NSF appears highest among patients with: chronic, severe kidney disease (GFR <30 mL/min/1.73m 2 ), or acute kidney injury. Screen patients for acute kidney injury and other conditions that may reduce renal function. For patients at risk for chronically reduced renal function (e.g. age > 60 years, hypertension or diabetes), estimate the glomerular filtration rate (GFR) through laboratory testing. For patients at highest risk for NSF, do not exceed the recommended MultiHance dose and allow a sufficient period of time for elimination of the drug from the body prior to re-administration. [see Warnings and Precautions (5.2) ] . WARNING: RISK ASSOCIATED WITH INTRATHECAL USE and NEPHROGENIC SYSTEMIC FIBROSIS See full prescribing information for complete boxed warning Intrathecal administration of gadolinium based contrast agents (GBCAs) can cause serious adverse reactions including death, coma, encephalopathy, and seizures. MultiHance is not approved for intrathecal use. (5.1) GBCAs increase the risk for nephrogenic systemic fibrosis (NSF) among patients with impaired elimination of the drugs. Avoid use of MultiHance in these patients unless the diagnostic information is essential and not available with non-contrast MRI or other modalities. The risk for NSF appears highest among patients with: chronic, severe kidney disease (GFR <30 mL/min/1.73m 2 ), or acute kidney injury. Screen patients for acute kidney injury and other conditions that may reduce renal function. For patients at risk for chronically reduced renal function (e.g. age >60 years, hypertension or diabetes), estimate the glomerular filtration rate (GFR) through laboratory testing. (5.2)
What it is approved for
magnetic resonance imaging (MRI) of the central nervous system (CNS) in adults and pediatric patients (including term neonates), to visualize lesions with abnormal blood-brain barrier or abnormal vascularity of the brain, spine, and associated tissues (1.1) magnetic resonance angiography (MRA) to evaluate adults with known or suspected renal or aorto-ilio-femoral occlusive vascular disease. (1.2) 1.1 Magnetic Resonance Imaging (MRI) of the Central Nervous System (CNS) MultiHance is indicated for intravenous use in magnetic resonance imaging (MRI) of the central nervous system (CNS) in adults and pediatric patients (including term neonates), to visualize lesions with abnormal blood-brain barrier or abnormal vascularity of the brain, spine, and associated tissues. 1.2 Magnetic Resonance Angiography (MRA) of Renal and Aorto-ilio-femoral Vessels MultiHance is indicated for use in magnetic re...
Show full text
sonance angiography (MRA) to evaluate adults with known or suspected renal or aorto-ilio-femoral occlusive vascular disease.
Source: FDA label on DailyMed, revised Mar 16, 2025
How it works
12.1 Mechanism of Action Gadobenate dimeglumine is a paramagnetic agent and, as such, develops a magnetic moment when placed in a magnetic field. The large magnetic moment produced by the paramagnetic agent results in a large local magnetic field, which can enhance the relaxation rates of water protons in its vicinity leading to an increase of signal intensity (brightness) of tissue. In magnetic resonance imaging (MRI), visualization of normal and pathological tissue depends in part on variations in the radiofrequency signal intensity that occur with 1) differences in proton density; 2) differ...
Show full text
ences of the spin-lattice or longitudinal relaxation times (T1); and 3) differences in the spin-spin or transverse relaxation time (T2). When placed in a magnetic field, gadobenate dimeglumine decreases the T1 and T2 relaxation time in target tissues. At recommended doses, the effect is observed with greatest sensitivity in the T1-weighted sequences.
Source: FDA label on DailyMed, revised Mar 16, 2025
FDA approvals, generics and biosimilars
| Application | Type | Holder | Approved | Products | Status |
|---|---|---|---|---|---|
| NDA021357 | Brand (NDA) | Bracco | Nov 23, 2004 | MULTIHANCE (4) | Marketed |
| NDA021358 | Brand (NDA) | Bracco | Nov 23, 2004 | MULTIHANCE MULTIPACK (2) | Marketed |
Source: FDA Drugs@FDA / Orange Book, Purple Book
Clinical trials
- Study of 18F-FFNP Breast PET/MRI
NCT06086704 · Phase 2 · recruiting · University of Wisconsin, Madison · started 2024-09-25 · 53 participants
- Comparative Effectiveness of Gadopiclenol for Evaluation of Adult Congenital Heart Anatomy and Hemodynamics
NCT06406517 · Phase 3 · completed · University of California, San Diego · started 2024-08-05 · 161 participants
- PSMA-Targeted 18F-DCFPyL PET/MRI for the Detection of Prostate Cancer
NCT04910425 · Phase 2 · withdrawn · Northwestern University · started 2023-06-17
- Comparison of Contrast Agents in Liver Magnetic Resonance (MR) for the Detection of Hepatic Metastases
NCT04973007 · Phase 4 · terminated · University of Colorado, Denver · started 2021-06-22 · 10 participants
- Effect on Body Movement and Mental Skills in Patients Who Received Gadolinium-based Contrast Media for Magnetic Resonance Examination Multiple Times Within 5 Years
NCT04373564 · Phase 4 · recruiting · Guerbet · started 2021-03-24 · 2,076 participants
Source: ClinicalTrials.gov
Recent research
- Relaxivity Performance of Gadopiclenol Versus Gadobenate Dimeglumine In Vitro, and Liver and Brain Imaging: A Randomized Crossover Study.
Heidenreich JF, Tamada D, Rice J, et al. · Investigative radiology · 2026 Dec 1
- Quantitative Hepatobiliary MRI for Early Prognostic Assessment After Liver Transplantation: Survival Prediction Using the Contrast Enhancement Index.
Asmundo L, Mariani L, Mazzarelli C, et al. · The British journal of radiology · 2026 Nov 5
- Gadolinium Retention in Pediatric Bone: Linear versus Macrocyclic MRI Contrast Agents.
Roberts DR, Moore RD, Harrison A, et al. · Radiology · 2026 Nov
- Impact of Different Degrees of Liver Iron Concentration on MRI Feature Assessment and LI-RADS v2018 Category Assignment for Hepatocellular Carcinoma.
Cao S, Li J, Su X, et al. · Journal of magnetic resonance imaging : JMRI · 2026 Nov
- Predicting Signal Intensity Profiles for Various MRI Contrast Agent Injection Strategies: Including Measurement of Relaxivities in Oxygenated Whole Human Blood for Gadopiclenol, Gadoterate Meglumine and Gadoteridol.
Maki JH, Barker AJ, Clark TJ, et al. · Journal of magnetic resonance imaging : JMRI · 2026 Oct 31
Source: PubMed
Medicare Part D spending
No Medicare Part D spending reported.
Source: CMS Medicare Part D Spending by Drug
Recalls
Class III · Sep 5, 2012 · Bracco Diagnostics Inc
Short Fill: The product is being recalled due to a potential underfill of the affected vials.
Bracco Diagnostics multihance (gadobenate dimeglumine) injection, 529 mg/mL, 20ml, Rx only, Manufactured for: Bracco Diagnostics Inc., Princeton, NJ 08543 USA, NDC 0270-5164-15
Class II · Sep 5, 2012 · Bracco Diagnostics Inc
Lack of Assurance of Sterility; Product recalled due to displacement of the aluminum crimp cap during product usage.
Multihance Multipack (gadobenate dimeglumine) injection, 529 mg/mL, Pharmacy Bulk Package - Not for Direct Infusion, For Intravenous Use, Rx only, a) 50 mL Single Dose Vial, b) 100 mL Single Dose Vial, Manufactured for: Bracco Diagnostics Inc. Princeton, NJ 08543 by Nycomed GmbH, 78224 Singen (Germany), NDC a) 0270-5264-16, b) 0270-5264-17.
Source: FDA enforcement reports via openFDA