DrugHub

Air Polymer-Type A: Dosage

Dosage and administration for air polymer-type a from the FDA-approved prescribing information.

Dosage and administration

Follow the dose your prescriber gives you. This is the label text for reference.

Confirm the patient is not pregnant prior to ExEm Foam administrations ( 2.1 ) Recommended dose is 2 mL to 3 mL of ExEm Foam by intrauterine infusion using a 5-Fr or larger catheter. Dose may be repeated in 2 mL to 3 mL increments, as needed, to achieve visualization of the fallopian tubes. Maximum total dose is 10 mL ( 2.2 ) See Full Prescribing Information for preparation and administration instructions. ( 2.3 ) 2.1 Important Pre-Administration Information To ensure that the patient is not pregnant prior to ExEm Foam administration [see Contraindications (4) and Warnings and Precautions (5.1) ]: Confirm that the patient has a negative pregnancy test within the 24 hours before ExEm Foam administration . Confirm the patient is in the pre-ovulatory phase of her menstrual cycle (cycle days 6 through 11). 2.2 Recommended Dosage The recommended initial dose of ExEm Foam is 2 mL to 3 mL by intrauterine infusion using a 5-Fr or larger catheter with luer connection. The dose may be repeated in increments of 2 mL to 3 mL, as needed, to achieve visualization of the fallopian tubes. Maximum total dose is 10 mL. 2.3 Preparation and Administration The ExEm Foam kit includes the following components: Syringe A containing 5 mL clear Gel [polymer type A (hydroxyethyl cellulose), glycerin and purified water] Syringe B containing 5 mL Sterile Purified Water Combifix Adapter (coupling device) Preparation Examine the package and do not use if package has been previously opened or damaged. Ensure the kit is at room temperature. Handle products following aseptic practices (e.g. sterile gloves). Generate foam by mixing Syringe A (Gel) with Syringe B (Sterile Purified Water) included in the package as described in Figure 1. Infuse foam within 5 minutes of reconstitution. FIGURE 1: Reconstitution of ExEm Foam Unscrew and discard the caps from each syringe when ready to prepare the foam. Push and screw Syringe A to one end of the Combifix Adapter. Push and screw Syringe B to the other end of the Combifix Adapter. Make sure these syringes are attached tightly to avoid loss of liquid when mixing. Push the plunger of one syringe vigorously to transfer, and begin mixing the contents from one syringe to the other syringe. Repeat this process at least 10 times. The reconstituted foam is completely milky white (opaque) in color After mixing, transfer all of the foam into one syringe, then disconnect the adapter and other syringe. Approximately 10 mL of ExEm Foam is created by mixing Syringe A of clear Gel with Syringe B of Sterile Purified Water. Infuse within 5 minutes of mixing to ensure adequate imaging. Figure Figure Administration Administer through a 5-Fr or larger catheter with luer connection only. If there is resistance when infusing foam use a larger catheter. Do not infuse forcefully. Infuse 1 mL of foam to confirm proper placement of the catheter tip in the cervix and access to the uterine cavity. Slowly infuse 2 mL to 3 mL of the foam at a time to avoid patient dis...

Show full text

comfort. Discard unused portion after use. 2.4 Imaging Guidance Conduct transvaginal ultrasound imaging in accordance with ultrasound manufacturer recommendations. ExEm Foam in the fallopian tube will appear as an echogenic line along the length of the tube on the image. A fallopian tube is classified as patent if ExEm Foam is observed to pass from the tube and spill into the peritoneal cavity. The tube will appear as a thin, bright line. A fallopian tube is classified as occluded if ExEm Foam is not observed to pass from the tube and spill into the peritoneal cavity. As secondary findings, (1) there may be no bright line due to no flow into the fallopian tube, or (2) the tubal lumen may appear distended and contrast flow might be observed only in the intramural or isthmic part of the tube.

Source: FDA label on DailyMed, revised Nov 8, 2023

← Back to Air Polymer-Type A overview